1. Pasiuna
This document provides comprehensive instructions for the installation, operation, and maintenance of the 60V 20A 1200W Buck Converter CC CV Step-Down Module (Model: XY6020L). This high-performance module is designed for durability and features CNC control for constant-voltage and constant-current regulation, a full-view dedicated power LCD for clear display, and support for serial communication via the standard MODBUS protocol. It offers precise control and stable performance for various power supply applications.

Figure 1: XY6020L Buck Converter with main board, display, and WiFi module.
2. Mga Detalye sa Produkto

Figure 2: Detalyadong mga parameter sa produkto ug mga mekanismo sa pagpanalipod.
| Parameter | Bili |
|---|---|
| Ngalan sa Produkto | Nc DC regulated power supply |
| Modelo sa Produkto | XY6020L |
| Pagsulod Voltage | 6.0~70V |
| Output Voltage | 0.0~60V |
| Output Current | 0~20.00A |
| Gahum sa Output | 0~1200W |
| Output Ripple Tipikal nga Bili | 100mV VPP |
| Maximum Output Voltage | (Input voltage + 1.1) - 2 |
| Pagsulod Voltage Resolusyon sa Pagsukod | 0.01V |
| Output Voltage Setting/Pagsukod Resolution | 0.01V |
| Kasamtangang Setting/Resolusyon sa Pagsukod | 0.01A |
| Pagsulod Voltage Katukma sa Pagsukod | ±1% + 5 ka numero |
| Output Voltage Setting/Pagsukod Katukma | ±0.4% + 1 digit |
| Output Kasamtangang Setting/Pagsukod Katukma | ±0.5% + 3 ka numero |
| Cooling Fan Activation Conditions | Kasamtangang > 2A, Gahum > 50W, Temperatura > 50°C |
| Cooling Fan Deactivation Conditions | Kasamtangang <1.5A, Gahum <45W, Temperatura <45°C |
Mga mekanismo sa pagpanalipod:
- External Temperature Protection (ETP): 0-110°C (default: off)
- Pagsulud sa Pagdugangtage Proteksyon (OVP): Default nga 71V
- Input Undervoltage Protection (LVP): 4.8-71V (adjustable; default: 4.8V)
- Output Overvoltage Proteksyon (OVP): 0-65V (default: 65V)
- Proteksyon sa Output Overcurrent (OCP): 0-22.0A (adjustable; default: 22.0A)
- Proteksyon sa Output Over-Power (OPP): 0-1250W (default: 1250W)
- Over Temperature Protection (OTP): 60-110°C (default: 95°C)
- Timeout Protection (OHP): 0-100h (adjustable; default: off)
- Proteksyon sa Sobra nga Kapasidad (OAH): 0-9999Ah (adjustable; default: disabled)
- Super Energy Protection (OPH): 0-9999Wh (adjustable; default: disabled)
3. Tapos sa Produktoview ug Components

Figure 3: Main board component layout.
The XY6020L Buck Converter consists of a main control board and a separate LCD display module. Key components and features include:
- Main Control Board: Features solid material input common mode inductor for low wave output, an intelligent temperature-controlled fan, and a large area heat sink for efficient cooling.
- Pagsulud sa mga Terminal: Positive input terminal (VIN+) and Negative input terminal (VIN-).
- Mga Output Terminal: Positive output pole (OUT+) and Negative output pole (OUT-).
- Power Supply Switch: A hard switch (OFF/ON) to power the module on or off.
- Serial Port Communication Port: For connecting to external communication modules.
- Ipakita ang Koneksyon: Connects the main board to the LCD display module.
- Key Press Koneksyon: For external control buttons.
- 10K NTC External Temperature Sensor Port: For external temperature monitoring.
- DIP Switch: Used to set a fixed output voltage when the base plate is used independently.
- LCD Display Module: Provides real-time display of voltage, current, power, capacity, energy, and time. Includes V/A, SW, and ON/OFF buttons, and an encoder knob for adjustments.

Figure 4: Product dimensions for the main board and display module.
Mga Dimensyon sa Produkto:
- Main Board: 109mm (gitas-on) x 72mm (lapad) x 42mm (gitas-on)
- Display Module: 79mm (gitas-on) x 43mm (lapad) x 27mm (gitas-on)
- Line Length (connecting display to board): 20cm
- Timbang sa Produkto: Base plate 183g + head module 43g + wire 2g x 2 = 230g in total
4. Pag-instalar
4.1. Pisikal nga Pag-instalar
Ensure the module is installed in a well-ventilated area to allow for proper heat dissipation, especially when operating at higher power levels. Use the provided dimensions for creating an appropriate enclosure or mounting solution.

Figure 5: Suggested installation opening size for the display module.
Suggested Opening Size for Display Module:
- Overall Cutout: Approximately 100mm x 64mm
- giladmon: Approximately 39mm (with a 12mm lip)
4.2. Mga Wiring Connections
Ikonektar ang input voltage source to the VIN+ and VIN- terminals. Connect your load to the OUT+ and OUT- terminals. Ensure correct polarity to prevent damage to the module and connected devices.
4.3. DIP Switch for Fixed Voltage Output
The base plate can be used independently for output current 0-20A. The DIP switch on the main board allows setting fixed output voltages. This is useful if you do not need the numerical control display for voltage pag-ayo.

Figure 6: DIP switch truth table for fixed output voltages.
Fixed Output Voltage Settings via DIP Switch:
- NC (Numerical Control Gear): This gear must be set when using the dial head numerical control to adjust pressure.
- 5V, 9V, 12V, 24V, 36V, 48V, 60V: Specific combinations of DIP switch positions (1, 2, 3) correspond to these fixed voltages. Refer to Figure 6 for the exact settings.
Note: If other special voltages are required, please contact customer service for customization.
5. Operasyon
5.1. Pagbutang Voltage ug Current

Figure 7: Setting voltage (CV) and current (CC) on the display module.
- Sa interface sa operasyon, pindota ang V / A buton aron makasulod sa setting voltage ug kasamtangan nga interface.
- Ang LCD downlink display SET, CV nagkidlap, nga nagpaila sa voltage pagpili.
- Pindota ang SW button or rotate the encoder to switch to current selection (CC nagkidlap).
- Adjust the desired voltage or current value by rotating the encoder knob.
- Pindota ang V / A button again to exit and save the settings to the operating interface. Alternatively, long press the V / A button for 2 seconds or wait for 6 seconds without any key operation. The system will automatically exit and save the settings.
5.2. Dali nga Pagtakda sa Voltage o Karon

Figure 8: Quick setting options for voltage (CV) or current (CC).
In the parameter setting interface (see Section 5.4), set the parameter FET sa CV or CC. Then, rotate the encoder in the operation interface to quickly set the voltage o kasamtangan.
5.3. Input and Output Voltage Ipakita

Figure 9: Displaying input voltage (IN) and output parameters.
Pindota ang SW button on the running interface to switch between the input voltage display and the output voltage/current/power display.
5.4. Parameter Setting Interface

Hulagway 10: Labaw naview of the parameter setting interface.
- Sa nagdagan nga screen, pugngi ang SW buton alang sa 2 segundos aron makasulod sa screen sa setting sa parameter.
- Press SW to switch the parameters to be set. Rotate the encoder to adjust the parameters.
- On the interface of Maximum Capacity (OAH)/Maximum Energy (OPH)/Maximum Running Time (OHP), press the ON/OFF button to enable or disable the corresponding function. If the function is disabled, "----" will be displayed.
- On the Maximum Capacity (OAH)/Maximum Energy (OPH) screen, hold down the ON/OFF button to select the capacity range (e.g., 9.999Ah, 99.99Ah, 999.9Ah, 9999Ah, 9.999Wh, 99.99WH, 999.9WH, 9999Wh).
- After the parameter setting is complete, hold down the SW button for 2 seconds to exit the setting screen. The settings are automatically saved.
5.5. View Power (W)/Capacity (Ah)/Energy (Wh)/Time (h)

Figure 11: Switching between different display modes for output statistics.
Sa interface sa operasyon, pindota ang buton sa encoder aron ibalhin ang display tali sa gahum (W), kapasidad (Ah), kusog (Wh), ug oras (h).
5.6. Locking Function
To prevent misoperation, you can lock the voltage ug kasamtangan nga mga setting.

Figure 12: Display lock symbol indicating activated locking function.
Sa interface sa operasyon, ipadayon ang encoder button sulod sa 2 segundos aron ma-lock ang voltage and current set. A lock symbol will appear on the display. After locking, long press the encoder button for 2 seconds to unlock.
5.7. Data Group Function
This product has 10 sets of data from Cd0 to Cd9. Data for Cd8=12V and Cd=24V cannot be adjusted. The data is saved in Cd0 by default.

Figure 13: Data group function interface showing setting voltage, current, and data group number.
- Pindota ug dugay ang V / A yawe alang sa 2 segundos sa pagsulod sa data group call out interface. Ang ibabaw nga duha ka linya nagpakita sa set voltage value (CV) and set current value (CC) of the data group, and the number of the downstream display group is CD1-CD9.
- Pindota ang V / A yawe sa pagbalhin tali sa setting voltage CV, setting current CC, and data set serial number Cd. Modify the parameter value through the encoder.
- Pagkahuman sa pagkumpirma sa grupo sa datos, pag-ayo nga press V / A aron makuha ang grupo sa datos ug mobalik sa interface sa operasyon.
5.8. Other Functions (Capacity/Energy/Running Time Statistics)

Figure 14: Explanation of capacity, energy, and running time statistics and settings.
8.1 Capacity/Energy/Running Time Statistics:
- After the power is turned ON, the statistics will be automatically started.
- After the power is turned OFF, the value of the previous state will be displayed.
- After the power is turned ON again, the record will be automatically restarted.
- Sa katugbang nga screen, pindota ug kupti ang ON/OFF key for 2 seconds to automatically clear the corresponding data.
8.2 Setting the Maximum Capacity (OAH), Maximum Energy (OPH), and Maximum Running Time (OHP):
- Setting OAH/OPH: When the OAH/OPH function is started and the statistical capacity/energy is higher than the set maximum capacity/energy, the power supply automatically shuts down the output and flashes "OAH" / "OPH". After the alarm is removed, the capacity/energy statistics will be cleared automatically.
- Setting OHP: After the OHP function is enabled, when the running time of the power supply is greater than the set maximum discharge time, the power output will be automatically turned off and "OHP" will blink. After the OHP alarm is lifted, the time statistics will be cleared automatically.
Kini nga function makab-ot ang usa ka maayo nga quantitative/timed power supply.
Note: When OAP/OPH and OHP functions are not enabled, the power supply will automatically record the capacity/energy and running time. After OAH/OPH and OHP functions are enabled, the power supply will automatically shut down the output after reaching the set value. After OHP function is enabled, the running time of power supply is countdown mode.
6. WiFi Module and APP Control
The XY6020L supports an optional WiFi module for remote control and monitoring via a mobile app or web interface. This allows for multi-machine communication and integration with smart home systems.

Figure 15: WiFi module and its features.
6.1. WiFi Module Features:
- Pagkontrol sa Mobile APP
- PC upper computer control
- LAN real-time communication
- External network control and viewing
- Support multi-machine communication
- Support Tmall Genie, Baidu Voice, Xiao Ai voice control switch
- Open source design
6.2. Sinilink Power System Communication Diagram:

Figure 16: Communication diagram showing Extranet (cloud) and Local Area Network (LAN) control options.
6.3. Mobile APP and PC Client Interface:

Hulagway 17: Examples of the mobile app and PC client interfaces for control and monitoring.
6.4. How to Connect WiFi:
Download the Sinilink app from your app store (search "Sinilink"). For PC software, download from http://www.sinilink.com/download/tools/Sinilink-Setup.exe.
Video 1: Demonstration of product setup and WiFi connection process.
WiFi Connection Steps (AP Mode):
- Power off the equipment and then turn on the power.
- Press and hold the pairing button on the WiFi module for 5 seconds. The indicator light should flash four times with an interval of 1 second.
- Press and hold the pairing button for 5 seconds again to confirm the flash of the indication point.
- Verify that the indicator flashes correctly.
- On your mobile phone, connect to the WiFi network named "Sinilinkproduct". The password is usually "12345678".
- Return to the Sinilink app, enter the device name and choose its classification.
- Start the connection process within the app.
- Once connected, you can control and monitor the device via the app.
7. Pagmentinar
- Paglimpyo: Keep the module clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
- bentilasyon: Ensure the cooling fan and heat sink are not obstructed to maintain proper airflow and prevent overheating.
- Mga koneksyon: Kanunay nga susihon ang tanan nga mga koneksyon sa mga kable aron masiguro nga kini luwas ug wala’y kaagnasan.
- Pagtipig: When not in use for extended periods, store the module in a dry, cool environment.
8. Pagsulbad sa problema
- Walay Output Voltage/Karon:
- Check input power supply. Ensure it is within the 6.0-70V DC range. This device is a buck converter and requires a DC input, not AC.
- Verify that the output is enabled (ON/OFF button on the display).
- Check for active protection mechanisms (OVP, OCP, OPP, OTP, LVP). If a protection is triggered, the output may be shut off. Refer to Section 5.4 for parameter settings and protection thresholds.
- Siguroha ang output voltage and current are set correctly (refer to Section 5.1).
- Sayup nga Voltage/Current Reading:
- Check wiring for loose connections or incorrect polarity.
- Ensure the measurement accuracy specifications (Table 1) are considered.
- Overheating sa Module:
- Verify that the cooling fan is operating when conditions (current > 2A, power > 50W, temperature > 50°C) are met.
- Ensure the heat sink is clear of obstructions and there is adequate ventilation.
- Reduce the load or input voltage if operating continuously at high power.
- Difficulty Adjusting Voltage/Karon:
- Ensure the display is not locked (refer to Section 5.6).
- Follow the steps in Section 5.1 carefully for setting parameters.
- Mga Isyu sa Koneksyon sa WiFi:
- Ensure the WiFi module is correctly installed and powered.
- Follow the AP mode connection guidance in Section 6.4 precisely.
- Verify your router supports 2.4GHz WiFi, as the module typically uses this frequency.
- Check that local network permissions are enabled on your mobile device.
9. Mga Tip sa Gumagamit
- Verify Input Power: Always double-check your input voltage and current capabilities before connecting to the buck converter. This device is a step-down converter, meaning the output voltage will always be lower than the input voltage. It cannot boost voltage.
- Tukma nga Wiring: Ensure all wiring is secure and correctly polarized. Loose connections can lead to unstable operation or damage.
- Cooling is Key: For applications requiring high current or power output, ensure the module has sufficient cooling. The integrated fan helps, but additional ventilation might be necessary in enclosed spaces.
- Gamita ang mga Grupo sa Datos: The 10 data groups (Cd0-Cd9) are very useful for quickly switching between frequently used voltage and current settings. Configure them for your common tasks.
- Mga Setting sa Lock: Use the locking function (Section 5.6) to prevent accidental changes to your voltage and current settings, especially in critical applications.
- Hilit nga Pag-monitor: If using the WiFi module, take advantage of the mobile app or PC client for remote monitoring and control, which can be very convenient for testing or long-term projects.
10. Garantiya ug Suporta
For warranty information, technical support, or inquiries regarding replacement parts (such as the display module), please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.