1. Pasiuna
This manual describes the assembly, installation, operation, and troubleshooting of the Anern Hybrid Solar Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.
1.1 Labaw sa Produktoview
The Anern Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings and easy operation.


1.2 Mga bahin
- Maayo nga sine wave inverter
- Ma-configure nga input voltage range para sa mga gamit sa balay ug personal nga kompyuter pinaagi sa LCD setting
- Ang pagkontrol sa karon nga pag-charge sa baterya pinahiuyon sa mga aplikasyon pinaagi sa setting sa LCD
- Ma-configure ang prayoridad sa AC / Solar Charger pinaagi sa setting sa LCD
- Nahiuyon sa mains voltage o gahum sa generator
- Auto-restart samtang nag-ayo ang AC
- Overload, over temperature, and short circuit protection
- Ang laraw sa Smart baterya charger alang sa na-optimize nga performance sa baterya
- Bugnaw nga pag-andar sa pagsugod
1.3 Batakang Sistema sa Arkitektura
The inverter/charger can be integrated into a complete running system that includes a generator or utility power source and PV modules. It can power various home and office appliances, including motor-type appliances up to 1.5HP.


2. Mga Instruksyon sa Kaluwasan
WARNING: Kini nga kapitulo adunay importante nga kaluwasan ug mga instruksyon sa pagpaandar. Basaha ug tipigi kini nga manwal alang sa umaabot nga pakisayran.
- Sa dili pa gamiton ang unit, basaha ang tanang instruksyon ug mga marka sa pagpasidaan sa unit, ang mga baterya, ug ang tanang angay nga mga seksyon niini nga manwal.
- PAHINUMDOM: Aron mamenosan ang risgo sa kadaot, i-charge lang ang deep-cycle nga lead acid type nga rechargeable nga mga baterya. Ang ubang mga matang sa mga baterya mahimong mobuto, hinungdan sa personal nga kadaot ug kadaot.
- Ayaw i-disassemble ang unit. Dad-a kini sa usa ka kwalipikado nga sentro sa serbisyo kung gikinahanglan ang serbisyo o pag-ayo. Ang sayop nga re-assembly mahimong moresulta sa risgo sa electric shock o sunog.
- Aron mamenosan ang risgo sa electric shock, idiskonekta ang tanang mga wiring sa dili pa mosulay sa bisan unsang pagmentinar o paglimpyo. Ang pagpalong sa yunit dili makapakunhod niini nga risgo.
- PAHINUMDOM: Ang mga kwalipikado nga kawani lamang ang maka-install niini nga aparato nga adunay baterya.
- WALA gyud pag-charge sa usa ka yelo nga baterya.
- Para sa labing maayong operasyon niining inverter/charger, palihug sunda ang gikinahanglan nga mga detalye aron mapili ang angay nga gidak-on sa kable. Importante kaayo nga gamiton sa husto kining inverter/charger.
- Pag-amping pag-ayo sa pagtrabaho gamit ang metal nga mga himan sa o sa palibot sa mga baterya. Adunay usa ka potensyal nga peligro nga mahulog ang usa ka himan aron mag-spark o short circuit nga mga baterya o uban pang mga bahin sa kuryente ug mahimong hinungdan sa pagbuto.
- Please strictly follow installation procedures when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
- MGA INSTRUKSYON SA GROUNDING: Kini nga inverter/charger kinahanglan nga konektado sa usa ka permanente nga grounded wiring system. Siguruha nga sundon ang mga lokal nga kinahanglanon ug regulasyon aron ma-install kini nga inverter.
- WALA gyud hinungdan sa mga short circuit sa AC output ug DC input. AYAW ikonektar sa mains kon ang mga short circuit sa DC input.
- Pasidaan: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, send this inverter/charger back to local dealer or service center for maintenance.
Inverter Use Notice:
- The starting power of inductive load electrical appliances shall be at least three times the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
- Please connect the circuit correctly according to the instructions, and install switches for each circuit.
- Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains, and load switches.
- Shutdown sequence: turn off the switches of load, PV, and mains, turn off the inverter, and finally turn off the battery.
3. Pag-setup
3.1 Pag-unpack ug Inspeksyon
Sa dili pa i-instalar, palihug susiha ang yunit. Siguruha nga walay nadaot sa sulod sa pakete. Kinahanglan nga nadawat na nimo ang yunit ug ang manwal sa paggamit.
3.2 Pagpangandam
Before connecting all wirings, take off the bottom cover by removing two screws.
3.3 Pag-mount sa Yunit
Tagda ang mosunod nga mga punto sa dili pa mopili kon asa i-install:
- Ayaw i-mount ang inverter sa mga materyales nga dali nga masunog.
- Ibutang sa usa ka solid nga nawong.
- I-install kini nga inverter sa lebel sa mata aron mabasa ang LCD display sa tanang oras.
- Alang sa husto nga sirkulasyon sa hangin aron mawala ang kainit, tugoti ang clearance nga gibanabana. 20 cm sa kilid ug gibanabana. 50 cm sa ibabaw ug sa ubos sa yunit.
- Ang temperatura sa palibot kinahanglan nga tali sa 0 ° C ug 55 ° C aron masiguro ang labing maayo nga operasyon.
- Ang girekomenda nga posisyon sa pag-install kinahanglan nga idikit sa dingding nga patindog.
- Be sure to keep other objects and surfaces clear to guarantee sufficient heat dissipation and space for removing wires.
ANGAY PARA SA PAGTAMBOT SA KONKRETONG O UBAN NGA DILI MASUNOG NGA LUWAS LAMANG.
I-instalar ang yunit pinaagi sa pag-screw sa duha ka screw. Girekomendar nga gamiton ang M4 o M5 nga mga screw.

3.4 Koneksyon sa Baterya
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. All wiring must be performed by a qualified personnel.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
| Modelo | Gidak-on sa Wire | Kable (mm²) | Bili sa torque (max) |
|---|---|---|---|
| 2.0KW/12V | 1 x 6AWG | 14 | 5 Nm |
| 3.2KW/24V | 1 x 6AWG | 14 | 5 Nm |
Follow these steps to implement battery connection:
- Kuhaa ang insulasyon nga manggas nga 18 mm para sa positibo ug negatibo nga mga konduktor.
- Isugyot nga ibutang ang bootlace ferrules sa tumoy sa positibo ug negatibo nga mga alambre nga adunay husto nga himan sa pag-crimping.
- Ikonektar ang tanang mga battery pack sama sa gipakita sa diagram.
- Insert the battery wires flatly into battery connectors of the inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity is correct at both the battery and the inverter/charger. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage sa serye.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 AC Input/Output Koneksyon
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 20A for 2.0KW and 30A for 3.2KW.
Attention: After 90s of mains power connection to the inverter, the machine is connected to the mains and starts to work.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Modelo | Gauge | Bili sa Torque |
|---|---|---|
| 2.0KW/12V | 12 AWG | 2 Nm |
| 3.2KW/24V | 12 AWG | 2 Nm |
Sunda kini nga mga lakang aron ipatuman ang koneksyon sa input/output sa AC:
- Sa dili pa mohimo og koneksyon sa AC input/output, siguroha nga ablihan una ang DC protector o disconnector.
- Kuhaa ang insulasyon nga manggas 10mm para sa unom ka konduktor. Ug mub-an ang phase L ug neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (⚠) first.
- ⚠ → Ground (yellow-green)
- L → LINE (brown o itom)
- N → Neutral (asul)
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws.
- L → LINE (brown o itom)
- N → Neutral (asul)
WARNING: Siguroha nga ang AC power source nadisconnect sa dili pa mosulay sa hardwire niini ngadto sa unit.
3.6 Koneksyon sa PV
PAHINUMDOM: Sa dili pa magkonektar sa PV modules, palihog i-install ug bulag ang DC circuit breaker tali sa inverter ug PV modules.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Modelo | Gidak-on sa Wire | Bili sa torque (max) |
|---|---|---|
| 2.0KW/12V | 1x10AWG | 2 Nm |
| 3.2KW/24V | 1x10AWG | 2 Nm |
Pagpili sa PV Module
When selecting proper PV modules, be sure to consider these parameters:
- Bukas nga sirkito VoltagAng e (Voc) sa mga PV module dili molapas sa max. PV array open circuit vol.tage sa inverter.
- Bukas nga sirkito Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 2.0KW | 3.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 150Vdc | |
| PV Array MPPT Voltage Sakup | 20~150Vdc | 30~150Vdc |
Taking a 250Wp PV module as an example, the recommended module configurations are:
| Espesipiko sa Solar Panel. (reference) | SOLAR INPUT (Max in serial: 4pcs) | Gidaghanon sa mga panel | Total nga gahum sa pag-input |
|---|---|---|---|
| 250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Mga Selyula: 60 | 2 pcs sa serial | 2 pcs | 500W |
| 3 pcs sa serial | 3 pcs | 750W | |
| 4 pcs sa serial | 4 pcs | 1000W |
PV Module Wire Koneksyon
Sunda kini nga mga lakang aron ipatuman ang koneksyon sa PV module:
- Kuhaa ang insulasyon nga manggas nga 10 mm para sa positibo ug negatibo nga mga konduktor.
- Isugyot nga ibutang ang bootlace ferrules sa tumoy sa positibo ug negatibo nga mga alambre nga adunay husto nga himan sa pag-crimping.
- Susiha ang saktong polarity sa koneksyon sa wire gikan sa mga PV module ug PV input connector. Dayon, ikonektar ang positive pole (+) sa connection wire ngadto sa positive pole (+) sa PV input connector. Ikonektar ang negative pole (-) sa connection wire ngadto sa negative pole (-) sa PV input connector. Girekomendar nga himan: 4mm blade screwdriver.
3.7 Katapusan nga Asembliya
After connecting all wirings, put the bottom cover back by screwing four screws.
4. Mga Instruksyon sa Pag-opera
4.1 Power ON/OFF
Once all wiring is properly connected, and the machine is connected to the battery, press the power switch (located on the side of the machine) to start the unit. The machine will not start if the mains or photovoltaic power is connected but the switch is off.
4.2 Operasyon ug Display Panel
The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.


LED Indicators
| LED Indicator | Kolor | Mga mensahe |
|---|---|---|
| AC/INV | Berde | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Berde | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| SAYOP | Pula | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
Function Keys
| Function Key | Deskripsyon |
|---|---|
| ESC | Aron mogawas sa setting mode |
| UP | Aron moadto sa miaging pagpili |
| UBOS | Aron moadto sa sunod nga pagpili |
| PAGSULOD | Aron makumpirma ang pagpili sa setting mode o pagsulod sa setting mode |
4.3 Setting sa LCD
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" to select setting programs. Then, press "ENTER" to confirm the selection or ESC to exit.
Setting Programs Overview
The manual provides detailed programs for configuring various aspects of the inverter's operation, including:
- Program 00: Exit setting mode (Escape, One-button restore setting options)
- Programa 01: Prayoridad sa tinubdan sa output (Utility first, Solar first, SBU priority, MKS priority)
- Programa 02: Pinakataas nga kuryente sa pag-charge (10A to 140A options)
- Programa 03: Volt sa input sa ACtage range (Appliances, UPS)
- Programa 05: Tipo sa Baterya (AGM, Flooded, User-Defined)
- Programa 06: Awtomatikong i-restart kung adunay sobra nga karga (Restart disable, Restart enable)
- Programa 07: Awtomatikong i-restart kung molapas sa temperatura (Restart disable, Restart enable)
- Programa 09: Kasubsob sa output (50Hz, 60Hz)
- Programa 10: Output voltage (220V, 230V, 240V)
- Programa 11: Pinakataas nga kuryente sa pag-charge sa utility (2A to 80A options)
- Programa 12: Setting voltage tudlo balik sa tinubdan sa utility (for MKS/SBU priority, 2.0KW/12V default 11.5V, 3.2KW/24V default 23V)
- Programa 13: Setting voltage point balik sa battery mode (for MKS/SBU priority, 2.0KW/12V default 13.5V, 3.2KW/24V default 27V)
- Program 14: Maximum battery discharge current (10A to 120A options)
- Programa 16: Prayoridad sa tinubdan sa charger (Solar first, Solar and Utility, Only Solar)
- Program 18: Alarm control (Alarm on, Alarm off)
- Programa 19: Awtomatikong pagbalik sa default nga display screen (Return to default, Stay at latest screen)
- Programa 20: Pagkontrol sa backlight (Backlight on, Backlight off)
- Program 22: Beeps while primary source is interrupted (Alarm on, Alarm off)
- Programa 23: Paglikay sa Sobra nga Karga (Bypass disable, Bypass enable)
- Program 25: Record fault code (Record enable, Record disable)
- Programa 26: Bulk charging voltage (CV voltage) (2.0KW/12V default 14.1V, 3.2KW/24V default 28.2V)
- Programa 27: Naglutaw nga vol sa pag-chargetage (2.0KW/12V default 13.5V, 3.2KW/24V default 27V)
- Programa 29: Ubos nga DC cut-off voltage (2.0KW/12V default 10.0V, 3.2KW/24V default 20.0V)
- Programa 30: Pagpapantay sa Baterya (Battery equalization, Battery equalization disable)
- Programa 31: Pagbalanse sa baterya voltage (2.0KW/12V default 14.6V, 3.2KW/24V default 29.2V)
- Programa 33: Oras nga gipares sa baterya (60min default)
- Programa 34: Na-equalize nga timeout sa baterya (120min default)
- Programa 35: Interval sa pagpapantay (30 days default)
- Programa 36: Gi-aktibo dayon ang equalization (Enable, Disable)
- Program 39: RGB control (Backlight on, RGB off)
- Programs 81-85: Time setting (Year, Month, Day, Hour, Minute)
- Program 86: Clear Energy (Enable, Disable)
- Programs 87-90: Timer settings for AC charging (Start Hour/Minute, Deadline Hour/Minute)
4.4 Setting sa Pagpakita
The LCD display information can be cycled by pressing the "Up" or "DOWN" keys. Selectable information includes: input voltage/output voltage, input frequency, PV voltage, PV input current, PV input power, charging current, charging power, battery voltage, output frequency, load porsyentotage, load in VA, load in Watt, DC discharging current, Daily power generation, Monthly power generation, Gross generation, Date, Time, and main CPU Version.
4.5 Deskripsyon sa Operating Mode
The inverter operates in various modes, each with specific behaviors and display indications:
- Mode sa pag-standby / Mode sa pagdaginot sa kuryente: The inverter is not outputting power, but can charge batteries. In power saving mode, output is off if the connected load is very low.
- Mode sa Linya: The unit provides output power from the mains and charges the battery. If 'solar first' is selected and solar energy is insufficient, solar and utility will power loads and charge the battery.
- Mode sa Baterya: The unit provides output power from the battery and PV power. PV energy will supply power to loads and charge the battery.
- Fault mode: Errors caused by internal circuit issues or external reasons like over temperature or output short circuit. PV energy and utility can still charge batteries.
5. Pagmentinar
5.1 Deskripsyon sa Pagpaparehas sa Baterya
The equalization function reverses the buildup of negative chemical effects like stratification and helps remove sulfate crystals from battery plates. This process is crucial for maintaining battery capacity and is recommended periodically.
Unsaon Pag-apply sa Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function by either of these methods:
- Pagbutang og equalization interval sa programa 35.
- Aktibo nga pagkaparehas dayon sa programa 36.
Kanus-a Magpaangay
Sa float stage, when the setting equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.
Equalize Charging Time and Timeout
Sa Equalize stage, the controller supplies power to charge the battery until the battery voltage reaches the equalization voltage. Kanunay nga-voltage regulation maintains this voltage until the set battery equalized time is reached. If the battery voltage does not rise to the equalization point within the equalized time, the charge controller will extend the time. If the voltage is still low after the timeout, the charge controller will stop equalization and return to the float stage.
5.2 Clearance and Maintenance for Anti-Dust Kit (Optional)
Every inverter is installed with an anti-dust kit from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust internal temperature. This kit also keeps dust out of your inverter and increases product reliability in harsh environments.
- Remove screws as shown in the manual.
- Kuhaa ang dustproof case ug kuhaa ang foam sa air filter.
- Limpyohi ang air filter foam ug ang dustproof case. Human sa paglimpyo, i-assemble pag-usab ang dust-kit balik sa inverter.
PAHIBALO: Ang anti-dust kit kinahanglang limpyohan gikan sa abog matag usa ka bulan.
6. Pagsulbad sa problema
6.1 Kasaypanan Reference Code
| Fault Code | Panghitabo sa Kasaypanan | Icon sa |
|---|---|---|
| 01 | Gi-lock ang fan kung ang inverter gipalong. | 01 |
| 02 | Labaw sa temperatura | 02 |
| 03 | Baterya voltage taas kaayo | 03 |
| 04 | Baterya voltage ubos kaayo | 04 |
| 05 | Output short circuited o sa ibabaw sa temperatura namatikdan sa internal converter component. | 05 |
| 06 | Output voltagtaas kaayo e. | 06 |
| 07 | Overload time out | 07 |
| 08 | Bus voltage taas kaayo | 08 |
| 09 | Ang hinay nga pagsugod sa bus napakyas | 09 |
| 51 | Sobra sa kasamtangan o surge | 51 |
| 52 | Bus voltage ubos kaayo | 52 |
| 53 | Ang humok nga pagsugod sa inverter napakyas | 53 |
| 55 | Labaw sa DC voltage sa output sa AC | 55 |
| 57 | Napakyas ang kasamtangan nga sensor | 57 |
| 58 | Output voltage ubos kaayo | 58 |
| 59 | PV voltage sobra sa limitasyon | 59 |
6.2 Warning Indicator
| Warning Code | Pagpasidaan nga Hitabo | Madungog nga Alarm | Icon nga nagkidlap |
|---|---|---|---|
| 01 | Ang fan kay naka-lock kung ang inverter on. | Beep tulo ka beses matag segundo | 01 |
| 04 | Ubos nga baterya | Beep kausa matag segundo | 04 |
| 07 | Sobra nga karga | Beep kausa matag 0.5 segundo | 07 |
| 10 | Pagminus sa gahum sa output | Duha ka beses nga beep matag 3 segundo | 10 |
| 15 | Ang enerhiya sa PV ubos. | Duha ka beses nga beep matag 3 segundo | 15 |
| 16 | PV voltagtaas e | Duha ka beses nga beep matag 3 segundo | 16 |
| E9 | Pagpaparehas sa baterya | Wala | E9 |
6.3 Kanunayng Gipangutana nga mga Pangutana (FAQ)
- Q: Whether to start with battery? A: Dili.
- Q: Whether it can directly supply power to the load? A: Oo.
- Q: Whether it can be connected to the grid? A: PV gives priority to power supply to the load, and extra to charge the battery. More can be integrated into the grid (needs to be based on local government policies). Note: 1600W and 3000W models cannot send remaining power to the grid.
- Q: How many solar panels need to be connected? A: To start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, with a maximum not exceeding 500V. For PRO-3.6KW/PLUS-6.2KW, the power of the solar panel should not exceed 6.2KW/6.5KW. For example, 10 pcs of 250W 30V solar panels connected in series.
- Q: Can inverters be connected in series or parallel? A: Dili.
- Q: Is this an on-grid tied inverter? Can it be output to utility? A: Yes. It is a hybrid inverter that can be both off-grid and on-grid connected.
- Q: Does the inverter have to be connected to the battery? A: Can be connected with or without battery, but without the battery, the voltage of the solar panel should exceed 360Vdc.
- Q: What types of batteries can be used? A: Lead-acid batteries, gel batteries, Lithium Iron Phosphate (LiFePo4), and lithium batteries can be used. A 24V battery is for the 3.6KW model, and a 48V battery for the 6.2KW model. The battery capacity cannot be less than 100AH.
- Q: Can it be used in air conditioners, water pumps, and wind turbines? A: It can be used in air conditioners, but not in water pumps and wind turbines.
- Q: Is it a high frequency inverter or a low frequency inverter? A: High frequency.
- Q: Can the utility be used to power the inverter when there is no sun? A: Oo.
- Q: How to choose the power of the inverter according to the household appliances? A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter should be at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
- Q: Is it possible to use PV, battery, grid supply at the same time? A: Yes. In the default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
7. Mga detalye
7.1 Mga Kinaiya sa Produkto
| Ngalan sa Hiyas | Bili sa Hiyas |
|---|---|
| Ngalan sa Brand | ANERN |
| Numero sa Modelo | SCI-ECO2000&3200 |
| Output Current | 80A |
| Gahum sa Output | 1 - 200 KW |
| Gidak-on | 390*270*100mm |
| Uri sa Output | SINGLE |
| Timbang | 4.4Kg/5.4Kg |
| Frequency sa Output | 50Hz/60Hz |
| Mao ang Smart Device | Oo |
| Sinugdanan | Mainland China |
| Sertipikasyon | CE |
| Pagsulod Voltage | 12V/24V |
| AC Pagsulod Voltage | 230VAC |
| Type | DC/DC Converters, DC/AC Inverters |
| Efficiency (Peak) PV to Inverter | 98% |
| Ngalan sa produkto | solar inverter 24V |
| RATED POWER | 2000KVA/1600W&3200KVA/3000W |
| Maximum nga Pag-charge Karon | 80A |
| Kasamtang sa Timbang sa AC Charge | 60A |
| porma sa balod | puro nga sine nga balud |
| Interface sa komunikasyon | WiFi |
| High-concerned nga kemikal | Wala |
7.2 Mga Espisipikasyon sa Line Mode
| INVERTER MODEL | 2.0KW/12V | 3.2KW/24V |
|---|---|---|
| Pagsulod Voltage Porma sa balod | Sinusoidal (utility o generator) | |
| Nominal nga Input Voltage | 230Vac | |
| Ubos nga Kapildihan Voltage | 170Vac±10V (UPS); 90Vac±10V (Home Appliances) | |
| Ubos nga Loss Return Voltage | 180Vac±10V (UPS); 100Vac±10V (Home Appliances) | |
| Taas nga Kapildihan Voltage | 280Vac±10V | |
| Taas nga Loss Return Voltage | 270Vac±10V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Ubos nga Kasubsob sa Pagkawala | 40±1Hz | |
| Ubos nga Loss Return Frequency | 42±1Hz | |
| Taas nga Kasubsob sa Pagkawala | 65±1Hz | |
| Taas nga Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Proteksyon | Circuit Breaker | |
| Efficiency (Linya Mode) | >95% (Rated R load, full charged ang baterya) | |
| Panahon sa Pagbalhin | 10ms | |
7.3 Mga Espisipikasyon sa Mode sa Inverter
| INVERTER MODEL | 2.0KW/12V | 3.2KW/24V |
|---|---|---|
| Gahum nga Output nga Gahum | 2.0KVA/2.0KW | 3.2KVA/3.2KW |
| Output Voltage Porma sa balod | Puro nga Sine Wave | |
| Output Voltage Regulasyon | 230Vac±5% | |
| Frequency sa Output | 50Hz | |
| Peak Efficiency | 92% | |
| Overload nga Proteksyon | 3s@ 150% load; 5s@ 100% ~ 150% load | |
| Pagdagsang Kapasidad | 2* rated nga gahum alang sa 1 segundos | |
| Nominal DC Input Voltage | 12Vdc | 24Vdc |
| Bugnaw nga Pagsugod Voltage | 11.5Vdc | 23.0Vdc |
| Ubos nga DC Warning Voltage @ load < 50% | 11.25Vdc | 22.5Vdc |
| Ubos nga DC Warning Voltage @ load ≥ 50% | 11.0Vdc | 22Vdc |
| Ubos nga DC Warning Return Voltage @ load < 50% | 11.75Vdc | 23.5Vdc |
| Ubos nga DC Warning Return Voltage @ load ≥ 50% | 11.5Vdc | 23Vdc |
| Ubos nga DC Cut-off Voltage @ load < 50% | 10.75Vdc | 21.5Vdc |
| Ubos nga DC Cut-off Voltage @ load ≥ 50% | 10.5Vdc | 21Vdc |
| Taas nga DC Recovery Voltage | 15.5Vdc | 31Vdc |
| Taas nga DC Cut-off Voltage | 16.0Vdc | 32Vdc |
| Walay Load Power Consumption | <38w | |
7.4 Mga Espisipikasyon sa Mode sa Pag-charge
Utility Charging Mode
| INVERTER MODEL | 2.0KW/12V | 3.2KW/24V |
|---|---|---|
| Algorithm sa Pag-charge | 3-Lakang | |
| AC Charging Current (Max) | 80Amp (@Vl/p=230Vac) | 80Amp (@Vl/p=230Vac) |
| Bulk nga Pag-charge Voltage Flooded Battery | 14.6 | 29.2 |
| Bulk nga Pag-charge Voltage AGM / Gel Battery | 14.1 | 28.2 |
| Naglutaw nga Charging Voltage | 13.5Vdc | 27Vdc |
MPPT Solar Charging Mode
| INVERTER MODEL | 2.0KW/12V | 3.2KW/24V |
|---|---|---|
| Max. Gahum sa PV Array | 2000W | 3200W |
| PV Array MPPT Voltage Sakup | 20~150Vdc | 30~150Vdc |
| Max. PV Array Open Circuit Voltage | 150Vdc | |
| Max solar nga pag-charge karon | 60Amp | |
| Max(AC+Solar) Pag-charge sa kasamtangan | 140Amp | |
7.5 Kinatibuk-ang Detalye
| INVERTER MODEL | 2.0KW/12V | 3.2KW/24V |
|---|---|---|
| Sertipikasyon sa Kaluwasan | CE | |
| Operating Temperatura Range | -10°C hangtod 50°C | |
| Temperatura sa Pagtipig | -15°C ~ 60°C | |
| Humidity | 5% ngadto sa 95% Relative Humidity (Non-condensing) | |
| Sukat (D * W * H), mm | 415X290X111 | |
| Net Timbang, kg | 7.2 | 7.3 |
8. Mga Tip sa Gumagamit
- Inductive Load Sizing: When connecting appliances with inductive loads (e.g., refrigerators, washing machines, air conditioners), ensure the inverter's power rating is at least three times the total power of these appliances to prevent startup issues or damage.
- Operasyon nga Walay Baterya: The inverter can operate without a battery, but the solar panel voltage must exceed 360Vdc for proper function.
- Solar Panel Voltage: For normal inverter startup, aim for a solar panel voltage between 300V-400V, not exceeding 500V.
- Paghiusa sa Sistema: This is a hybrid inverter, capable of both off-grid and on-grid connections. It prioritizes PV power, supplementing with battery and utility power when solar input is insufficient.
- Regular nga Pagmentinar: Clean the anti-dust kit monthly to ensure optimal performance and longevity of the inverter.
9. Garantiya ug Suporta
For warranty information, technical support, or service inquiries, please contact your local dealer or the manufacturer directly. Refer to the official product website or your purchase documentation for specific contact details and warranty terms.
A user manual in PDF format is available for download from the manufacturer's website for detailed instructions and diagrams: Anern Hybrid Solar Inverter User Manual (PDF)