kamoer KK1800

Manwal sa Instruksyon sa Ulo sa Pump sa Peristaltic sa Kamoer KK1800

Modelo: KK1800

Pasiuna

The Kamoer KK1800 Peristaltic Pump Head is a precision component designed for accurate fluid metering. It features durable stainless steel rotors and an imported engineering plastic body, ensuring long life and high performance. This pump head is specifically compatible with Kamoer UIP2 WIFI Peristaltic Pumps and other specified models, offering easy operation and quick replacement of pump tubes. This manual provides essential information for the safe and efficient use of your KK1800 pump head.

Setup

  1. Pag-unpack: Carefully remove the KK1800 pump head from its packaging. Inspect for any signs of damage.
  2. Pag-mount:

    The KK1800 pump head is designed for secure attachment to a compatible main pump unit (e.g., UIP2 WIFI Peristaltic Pump). Use the provided mounting screws to fix the pump head firmly in place.

    Kamoer KK1800 pump head with mounting screws

    Image: Kamoer KK1800 pump head showing the mounting screw points for installation onto a main pump unit.

    The underside of the pump head features a robust internal structure for stable mounting.

    Ubos view of Kamoer KK1800 pump head

    Hulagway: Ilalom nga bahin view of the KK1800 pump head, highlighting its imported engineering plastic body and internal mounting structure.

  3. Pag-instalar sa tubo:

    The KK1800 pump head allows for easy and quick replacement of pump tubes. To install or replace tubing:

    • Gently open the pump head mechanism.
    • Insert the appropriate size pump tube (refer to specifications for compatible sizes and wall thicknesses) into the channel.
    • Close the pump head mechanism securely to ensure the tube is properly compressed by the rotors.
    Kamoer KK1800 pump head open and closed positions

    Image: Diagram illustrating the "Open" and "Close" positions of the Kamoer KK1800 pump head for easy pump tube replacement.

  4. Connecting to Main Pump: Ensure the pump head is correctly aligned and connected to the motor shaft of your UIP2 WIFI Peristaltic Pump or other compatible host.
  5. Stacking Multiple Pump Heads (Optional): For applications requiring multiple channels, KK1800 pump heads can be stacked to save space and reduce overall system costs.Multiple Kamoer KK1800 pump heads stacked on a main unit

    Image: Illustration of multiple KK1800 pump heads stacked onto a Kamoer main pump unit, demonstrating a space-saving configuration.

Mga Instruksyon sa Pag-opera

The Kamoer KK1800 pump head operates as part of a peristaltic pump system. Once installed on a compatible main pump (e.g., UIP2 WIFI), its operation is controlled by the main unit.

  1. Gahum sa: Ensure the main pump unit is connected to a power source and turned on.
  2. Fluid Connection: Connect the inlet and outlet tubing to your fluid source and destination, ensuring all connections are secure and leak-free.
  3. Pag-adjust sa Rate sa Pag-agos: The flow rate is determined by the main pump's motor speed and the installed pump tube's dimensions. Refer to the main pump's manual for specific control instructions. The table below provides reference flow rates for various tube sizes and rotor configurations at 500 RPM.
    Reference Flow Rate (Unit: ml/min) at 500 RPM
    Code sa tubo sa bombaMetric: Inner diameter (mm) x Outer diameter (mm)Inch system: Inner diameter (in) x Outer diameter (in)Materyal nga tubo sa bombaKatulin sa pagtuyok3 rotors (ml/min)6 rotors (ml/min)
    14#1.6x4.81/16x3/16BPT500rpm1299.5
    19#2.4x5.63/32x7/32290190
    16#3.2x6.41/8x1/4480365
    25#4.8x8.03/16x5/16950575
    17#6.4x9.61/4x3/81480700
    18#7.9x11.15/16x7/162190950
    15#4.8x9.83/16x3/8Silipo nga tubo500rpm940-
    24#6.4x11.41/4x7/161490-

    Image: Table showing reference flow rates (ml/min) for various pump tube codes, inner/outer diameters (metric and inch), pump tube materials (BPT, Silicone), and rotor configurations (3 or 6 rotors) at a rotating speed of 500 RPM.

Pagmentinar

Regular maintenance ensures the longevity and optimal performance of your KK1800 pump head.

  1. Tubing Replacement: Pump tubing is a consumable part and should be replaced periodically, depending on usage and the type of fluid being pumped. The KK1800 is designed for easy tube replacement. Always use compatible tubing with the correct wall thickness.
  2. Paglimpyo:
    • Disconnect the pump head from the main unit and power supply before cleaning.
    • Clean the exterior of the pump head with a soft, damp cloth. Avoid using harsh chemicals that could damage the plastic body.
    • If fluid has leaked into the pump head mechanism, carefully clean the area, ensuring no residue affects the rotor movement.
  3. Rotor Inspection: Periodically inspect the stainless steel rotors for any signs of wear, corrosion, or damage. While durable, extreme conditions or abrasive fluids can affect their lifespan.
  4. Kinatibuk-ang Inspeksyon: Check all mounting screws and connections to ensure they remain tight and secure.

Pag-troubleshoot

If you encounter issues with your KK1800 pump head, refer to the following common problems and solutions:

  • No Flow or Inconsistent Flow:
    • Check if the pump head is securely closed and the tubing is properly seated.
    • Inspect the pump tubing for kinks, blockages, or wear. Replace if necessary.
    • Ensure the main pump unit is powered on and operating correctly.
    • Verify that the fluid source is not empty and there are no air bubbles in the line.
  • Leakage:
    • Ensure the pump tubing is correctly installed and the pump head is fully closed.
    • Check the tubing for cracks or damage. Replace worn tubing.
    • Verify that all connections to the fluid source and destination are tight.
    • A user reported needing "the rubber between the head and Machine". This suggests checking the seals or O-rings if present, or ensuring the tubing itself forms a proper seal within the head.
  • Talagsaong Kasaba:
    • Ensure the pump head is securely mounted and all screws are tightened.
    • Check for any foreign objects obstructing the rotors.
    • Inspect the rotors for damage or excessive wear.

Mga detalye

HiyasBili
ModeloKK1800 (Pump head)
Ngalan sa Brandkamoer
AplikasyonPagsukud
IstrukturaDiaphragm Pump (Note: This is a peristaltic pump head, often categorized under diaphragm for general pump types)
Standard o NonstandardEstandard
PressureUbos nga Presyon
PaggamitTubig
SinugdananCHINA
SertipikasyonCE, RoHS
High-concerned nga kemikalWala
Type sa motorNeed to adapt to the motor
Sakup sa agos0.1ml/min~2190ml/min (depending on tubing and rotor configuration)
TimbangMga 560g
Materyal nga tubo sa bombaSilicone (200H), BPT
Katulin sa pagtuyok500rpm (reference)
Gidaghanon sa mga rotors3 rotors (available in 3/6 rotor options)
Code sa tubo sa bomba14#, 15#, 16#, 17#, 18#, 19#, 24#, 25#
Pump tube wall thickness1.6mm, 2.5mm
Compatible nga mga produktoUIP2 WIFI, UIP WIFI-E, Med57-KK1800

Image: Diagram showing the dimensions of the Kamoer KK1800 pump head (105.5mm height, 94.5mm length, 54.5mm width) and a separate view of the 3-rotor assembly.

Kamoer KK1800 pump head dimensions and 3-rotor assembly

Garantiya ug Suporta

For warranty information and technical support, please contact your original point of purchase or the Kamoer Official Store. Keep your purchase receipt as proof of purchase.

Mga Tip sa Gumagamit

  • Pagpadayon sa Tubing: Regularly inspect and replace pump tubing, especially if you notice changes in flow rate or signs of wear. The KK1800's design makes this process very straightforward.
  • Susihon ang mga Selyo: If experiencing leaks, ensure all tubing connections are tight and that any internal seals or "rubber" components are correctly seated and free from damage.
  • Pagdaginot sa luna: If your application requires multiple fluid channels, consider stacking multiple KK1800 pump heads on a single main pump unit to optimize space and reduce equipment costs.
  • Katukma: The KK1800 offers higher precision compared to the CK15 model, making it suitable for applications requiring accurate metering.

May Kalabutan nga mga Dokumento - KK1800

Si Preview Kamoer UIP WIFI E Smart Peristaltic Pump User Manual
Komprehensibo nga manwal sa paggamit alang sa Kamoer UIP WIFI E Smart Peristaltic Pump, nga nagdetalye sa mga bahin niini, mga mode sa operasyon (Pagpadayon, Ration, Remote), mga setting sa sistema, pagmentinar, ug teknikal nga mga detalye.
Si Preview Kamoer UIP WIFI E Smart Peristaltic Pump: Quick Start Guide ug Technical Specifications
Dali nga giya sa pagsugod ug teknikal nga mga detalye alang sa Kamoer UIP WIFI E Smart Peristaltic Pump, nga nagdetalye sa mga bahin niini, interface, koneksyon sa app, ug impormasyon sa warranty.
Si Preview KCP-KK300-D Adjustable Peristaltic Pump Manwal sa Gumagamit
User manual para sa Kamoer KCP-KK300-D adjustable peristaltic pump, nagdetalye sa mga feature niini, specifications, operating conditions, interface description, ug safety precautions.
Si Preview Kamoer M1-STP Smart Peristaltic Pump Product Manual
Kini nga manwal naghatag ug detalyadong impormasyon sa Kamoer M1-STP Smart Peristaltic Pump, lakip ang mga feature niini, mga detalye, mga depinisyon sa modelo, mga pagpatin-aw sa interface, ug mga aksesorya. Gisakup niini ang mga kinaiya sa pasundayag ug sagad nga aplikasyon sa mga setting sa laboratoryo ug industriya.
Si Preview Kamoer FX-STP WIFI Peristaltic Pump User Manual
Manwal sa paggamit sa Kamoer FX-STP WIFI Peristaltic Pump, nga nagdetalye sa pag-instalar, pag-setup, operasyon, mga advanced setting, ug pag-troubleshoot. Pagkat-on unsaon pagkonektar ug pagkontrol sa bomba pinaagi sa Kamoer Remote app.
Si Preview Kamoer KLVP3 Micro Diaphragm Pump - Manwal sa Produkto ug Mga Detalye
Komprehensibo nga manwal sa produkto alang sa Kamoer KLVP3 Micro Diaphragm Pump. Ang mga detalye naglakip sa teknikal nga mga detalye, mga kinaiya sa pasundayag, tipikal nga mga aplikasyon, asembliya, mga sukat, ug pagkontrol sa motor alang sa pagbalhin sa fluid.