Discovery LHD 8-32X56SFIR FFP-Z

Discovery LHD 8-32X56SFIR FFP-Z Riflescope

Manwal sa Instruksyon

Model: LHD 8-32X56SFIR FFP-Z

1. Pasiuna

Thank you for choosing the Discovery LHD 8-32X56SFIR FFP-Z Riflescope. This high-performance optical sight is designed for precision shooting, featuring a First Focal Plane (FFP) reticle, ZERO STOP functionality, and HD bright glass for superior clarity. This manual provides essential information for the proper setup, operation, and maintenance of your riflescope to ensure optimal performance and longevity.

2. Impormasyon sa Kaluwasan

  • Always handle firearms and optical equipment with extreme care.
  • Never look directly at the sun or any bright light source through the riflescope, as this can cause permanent eye damage.
  • Ensure the firearm is unloaded and pointed in a safe direction before mounting or adjusting the riflescope.
  • Keep the riflescope and its accessories out of reach of children.
  • Avoid dropping or subjecting the riflescope to severe impacts, which can damage internal components.

3. Mga Sulod sa Pakete

Upon opening your Discovery LHD 8-32X56SFIR FFP-Z Riflescope package, please verify that all the following items are included:

  • Discovery LHD 8-32X56SFIR FFP-Z Riflescope
  • Mga Cap sa Lens
  • Sunshade
  • Chamois Cleaning Cloth
  • Manwal sa Instruksyon
  • Warranty Card
Included accessories: lens caps, sunshade, cleaning cloth, manual, and warranty card.
Hulagway 1: Giapil nga mga Kagamitan

4. Tapos sa Produktoview

Familiarize yourself with the key components of your riflescope:

Close-up of riflescope showing Magnification Adjustment Ring and Locking Diopter.
Figure 2: Magnification Adjustment Ring and Locking Diopter
  • Magnification Adjustment Ring: Used to change the magnification level (8x to 32x).
  • Locking Diopter: Adjusts the focus of the reticle to your eye.
Riflescope turrets with Zero Stop, Illumination Turret, and Parallax Adjustment.
Figure 3: Turrets (Zero Stop, Illumination, Parallax)
  • Elevation Turret (Top): Adjusts vertical point of impact. Features ZERO STOP.
  • Windage Turret (Right): Adjusts horizontal point of impact.
  • Illumination Turret (Left, top): Controls the brightness of the reticle illumination.
  • Parallax Adjustment (Left, bottom): Corrects parallax error for different distances.

5. Mga detalye

The following table outlines the key specifications for the Discovery LHD 8-32X56SFIR FFP-Z Riflescope:

Detailed specifications for Discovery LHD 8-32X56SFIR-Z riflescope.
Hulagway 4: Detalyadong Detalye
FeatureEspesipikasyon
ModeloLHD 8-32X56SFIR-Z
Pagpadako8x-32x
Focal PlaneUnang Focal Plane (FFP)
Natad sa View15.2FT (4.7m) - 3.8FT (1.2m) / 100YDS
Exit Pupil6.6-1.7mm
Sakit sa mata3.5in (9.0cm) - 3.4in (8.6cm)
I-klik ang Bili0.1 MRAD (Note: Some variants may use 1/4 MOA)
Total Adjustment Elevation36 MRAD
Total Adjustment Windage18 MRAD
Laki sa Lens sa Tumong56mm
Diametro sa tubo34mm
I-adjust ang Focus25 YDS - ∞
Gitas-on14.9in (378mm)
Timbang35.6 oz (1010g)
Gidan-ag nga ReticleOo
Dili MakakuratOo
Water-proofOo (IPX6)
Fog-ProofOo
Nitrogen FilledOo
kilid view of riflescope with dimensions in inches and millimeters.
Figure 5: Riflescope Dimensions

6. Pag-setup

6.1. Mounting the Riflescope

  1. Select appropriate scope rings and a mount compatible with your firearm and the riflescope's 34mm tube diameter.
  2. Securely attach the mount to your firearm's rail system according to the mount manufacturer's instructions.
  3. Place the riflescope into the rings, ensuring proper eye relief and reticle alignment.
  4. Tighten the scope ring screws evenly and gradually to the manufacturer's recommended torque specifications. Avoid over-tightening.

6.2. Pag-adjust sa Diopter

The diopter adjustment focuses the reticle to your individual eyesight, ensuring a sharp reticle image.

  1. Point the riflescope at a plain, bright background (e.g., a clear sky or a blank wall).
  2. Look through the scope and quickly glance away.
  3. While quickly glancing back, adjust the locking diopter ring (Figure 2) until the reticle appears perfectly sharp and clear.
  4. Once adjusted, lock the diopter ring in place if it has a locking mechanism.

6.3. Zeroing the Riflescope

Zeroing aligns the point of impact with the point of aim at a specific distance.

  1. Mount the riflescope on your firearm and ensure it is securely fastened.
  2. Use a bore-sighting device or fire a shot at a target at a short range (e.g., 25 yards) to get on paper.
  3. Adjust the elevation and windage turrets (Figure 3) to move the point of impact towards the point of aim. Each click of the turret moves the impact point by 0.1 MRAD at 100 yards (or 1 cm at 100 meters).
  4. Repeat the process at your desired zeroing distance (e.g., 100 yards) until the point of impact consistently matches the point of aim.

6.4. Setting the ZERO STOP

The ZERO STOP feature allows you to quickly return to your zero setting without looking at the turret markings.

  1. After zeroing your riflescope, ensure the elevation turret is at your desired zero position.
  2. Refer to the specific instructions for your ZERO STOP mechanism (typically involves loosening a set screw or ring, rotating a collar to the zero mark, and then re-tightening). Consult Figure 3 for the location of the ZERO STOP mechanism.
  3. Once set, the elevation turret will stop at your zero position when rotated counter-clockwise.

6.5. Parallax Adjustment

Parallax is the apparent shift in the reticle's position relative to the target when your eye moves. The parallax adjustment corrects this for different distances.

  1. With the riflescope mounted and aimed at a target, rotate the parallax adjustment knob (Figure 3) to the approximate distance of your target.
  2. While looking through the scope, move your head slightly up and down, or side to side. If the reticle appears to move relative to the target, adjust the parallax knob until there is no apparent movement.
  3. The image and reticle should both be sharp and clear, and the reticle should remain stationary on the target regardless of minor head movement.

7. Naglihok

7.1. Magnification Adjustment

Rotate the magnification adjustment ring (Figure 2) to select your desired magnification level between 8x and 32x. The First Focal Plane (FFP) reticle will scale proportionally with the magnification.

7.2. Reticle Illumination

The illumination turret (Figure 3) controls the brightness of the reticle. Rotate the knob to turn the illumination on/off and adjust through various brightness settings. This feature is useful in low-light conditions.

7.3. First Focal Plane (FFP) Reticle

The LHD 8-32X56SFIR FFP-Z features a First Focal Plane reticle. This means the reticle physically grows and shrinks in proportion to the target image as you adjust the magnification. This ensures that all reticle subtensions (e.g., mil-dots, hash marks) remain accurate at any magnification setting, which is crucial for range estimation and holdovers.

First Focal Plane (FFP) reticle scaling at 8X, 16X, and 32X magnification.
Figure 6: FFP Reticle Scaling Example

8. Pagmentinar

8.1. Paglimpyo

  • Mga lente: Use the provided chamois cleaning cloth or a high-quality lens cleaning pen/solution. Gently brush off any loose dust or debris before wiping. Avoid using harsh chemicals or abrasive materials.
  • Lawas: Wipe the riflescope body with a soft, damp panapton. Alang sa gahi nga hugaw, ang usa ka malumo nga solusyon sa sabon mahimong gamiton, sundan sa pagpahid sa usa ka limpyo, damp panapton.

8.2. Pagtipig

  • Store the riflescope in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ensure lens caps are in place to protect the lenses from dust and scratches.
  • If storing for extended periods, remove the battery from the illumination turret to prevent corrosion.

9. Pagsulbad sa problema

  • Malabong nga Imahe: Adjust the diopter for reticle sharpness and the parallax knob for target sharpness. Ensure lenses are clean.
  • No Reticle Illumination: Check if the battery is correctly installed and has sufficient charge. Replace the battery if necessary. Ensure the illumination turret is turned to an 'ON' setting.
  • Inconsistent Point of Impact: Verify that the scope rings and mount are securely tightened. Check for any loose components on the firearm. Ensure proper shooting technique.
  • Reticle Movement: If the reticle appears to move when you shift your eye, re-adjust the parallax for the target distance.

10. Mga Tip sa Gumagamit

  • Caliber Compatibility: While this riflescope is robust, always ensure it is compatible with the recoil of your specific firearm's caliber. Consult your firearm's manual or a qualified gunsmith if unsure.
  • Practice Eye Relief: Consistent eye relief is crucial for a full, clear sight picture and to avoid scope bite. Practice your shooting stance to maintain a consistent head position.
  • Turret Tracking: Before critical use, perform a 'box test' to verify the turrets track accurately and return to zero reliably.

11. Garantiya ug Suporta

Discovery Optics provides a warranty for this product against defects in materials and workmanship. Please refer to the included warranty card for specific terms, conditions, and duration of coverage. For technical support, service, or warranty claims, please contact your authorized Discovery Optics dealer or visit the official Discovery Optics website alang sa impormasyon sa pagkontak.

May Kalabutan nga mga Dokumento - LHD 8-32X56SFIR FFP-Z

Si Preview Discovery Scope Set 2 Manwal sa Gumagamit sa Mikroskopyo ug Teleskopyo
Komprehensibo nga manwal sa paggamit para sa Discovery Scope Set 2, lakip ang mga instruksyon sa paggamit, pag-atiman, pagmentinar, ug mga detalye para sa mikroskopyo ug teleskopyo. Adunay sulod nga daghang pinulongan ug detalyado nga giya.
Si Preview Discovery 900x Power Microscope Instruction Manual
Instruction manual for the Discovery 900x Power Microscope, detailing parts, usage, and safety warnings for biological experiments.
Si Preview Discovery Extreme Chemistry Science Kit: Mga Eksperimento ug mga Instruksyon
Detalyado nga mga instruksyon ug mga giya sa eksperimento para sa Discovery Extreme Chemistry STEM Science Kit. Pagkat-on mahitungod sa mga reaksiyon sa kemikal, mga asido, mga base, ug uban pa uban sa 40 ka makalingaw nga mga kalihokan para sa edad nga 8 pataas.
Si Preview Discovery Scope Set 2 Telescope ug Microscope User Manual
Usa ka komprehensibo nga manwal sa paggamit alang sa Discovery Scope Set 2, usa ka bag-o nga teleskopyo ug microscope kit nga gidisenyo alang sa mga bata ug mga nagtinguha nga mga astronomo. Kini nga giya naghatag og detalyado nga mga instruksyon sa pag-setup, paggamit, pag-atiman, pagmentinar, ug mga pag-amping sa kaluwasan alang sa duha ka optical nga instrumento.
Si Preview Discovery Artisan 64 Digital Microscope User Manual
Komprehensibo nga manwal sa paggamit para sa Discovery Artisan 64 Digital Microscope ni Levenhuk. Pagkat-on mahitungod sa mga bahin, pag-assemble, operasyon, software, mga detalye, ug pagmentinar niini para sa detalyado nga mikroskopikong obserbasyon.
Si Preview Discovery Star Sky P1/P2 Planetarium: Manwal sa Gumagamit, Mga Feature, ug Giya sa Kaluwasan
Detalyado nga manwal sa paggamit para sa Discovery Star Sky P1/P2 Planetarium. Pagkat-on mahitungod sa mga bahin niini sama sa star projection, musika, rotation, remote control, ug operasyon sa baterya. Naglakip sa mga importanteng pasidaan sa kaluwasan ug impormasyon sa warranty gikan sa Levenhuk.