FLUKE 15B MAX

Manwal sa Paggamit sa FLUKE 15B MAX Digital Multimeter

Model: 15B MAX | Brand: FLUKE

1. Pasiuna

The FLUKE 15B MAX is an economical, multi-functional digital multimeter designed for high-precision electrical measurements. It features fully automatic ranging, making it user-friendly for various applications. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your FLUKE 15B MAX multimeter.

FLUKE 15B MAX Digital Multimeter with red and black test leads

Figure 1: FLUKE 15B MAX Digital Multimeter with included test leads.

Pangunang mga bahin:

  • Input Alert™: A safety feature designed to reduce efficiency loss and potential hazards from incorrect fuse handling. It provides an alarm effect through flashing lights, especially useful in noisy or dark environments.
  • Taas nga Katukma nga Pagsukod: Capable of accurate readings for voltage, current, resistance, and capacitance.
  • Automatic Ranging: Simplifies operation by automatically selecting the correct measurement range.
  • Compact nga Disenyo: Ergonomic and portable for on-site testing.
  • Optional 1mm Extra Tip Test Pen: Available with 15B MAX-02 and KIT models, this thinner tip allows for precise measurements on circuit board device pins, helping to avoid short circuits in small spaces.

2. Impormasyon sa Kaluwasan

WARNING: To avoid possible electric shock, fire, or personal injury, read all safety information before you use the product. Always use the meter as specified in this manual; otherwise, the protection provided by the meter might be impaired.

  • Always disconnect power to the circuit under test before connecting or disconnecting test leads.
  • Ayaw pag-apply labaw pa sa gi-rate nga voltage, ingon nga gimarkahan sa metro, taliwala sa mga terminal o taliwala sa bisan unsang terminal ug yuta nga yuta.
  • Pag-amping sa voltages above 30 V AC RMS, 42 V peak, or 60 V DC. These voltagNaghatag kini usa ka peligro nga makurat.
  • Use the correct terminals, function, and range for all measurements.
  • Check the continuity of the test leads before use. Do not use damaged test leads.
  • Do not operate the meter if it is damaged or if the case is open.
  • Ayaw pag-operate ang metro palibot sa gas, alisngaw, o abug.
  • Pagsunud sa lokal ug nasudnon nga mga code sa kahilwasan. Kinahanglan gamiton ang mga gamit nga panalipod aron malikayan ang pagkaguba ug pagkasamad sa arc arc diin gibutyag ang peligro nga mga live conductor.
  • The meter is rated for CAT III 600V and CAT II 1000V. Ensure your measurement category matches the meter's rating.

3. Mga Sulod sa Pakete

The contents of your FLUKE 15B MAX package may vary depending on the specific model purchased. Please verify that all items are present upon unboxing.

Typical Contents by Model:

  • FLUKE 15B MAX-01 Digital Multimeter:
    • FLUKE 15B MAX Digital Multimeter Unit
    • TL75 Test Probe with two protective caps
    • 2 AA Batteries (Note: Batteries may not be included due to shipping regulations in some regions.)
    • Manwal sa Gumagamit
  • FLUKE 15B MAX-02 Digital Multimeter:
    • FLUKE 15B MAX Digital Multimeter Unit
    • TL31 Special Tip Pen with two protective caps
    • 2 AA Batteries (Note: Batteries may not be included due to shipping regulations in some regions.)
    • Manwal sa Gumagamit
  • FLUKE 15B MAX KIT Digital Multimeter:
    • FLUKE 15B MAX Digital Multimeter Unit
    • TL75 Test Probe with two protective caps
    • TL31 Special Tip Pen with two protective caps
    • 2 AA Batteries (Note: Batteries may not be included due to shipping regulations in some regions.)
    • Manwal sa Gumagamit

4. Pag-setup

4.1. Pag-instalar sa Baterya

  1. Ensure the multimeter is turned OFF.
  2. Pangitaa ang tabon sa kompartamento sa baterya sa likod sa yunit.
  3. Paggamit og screwdriver aron maablihan ang kompartamento sa baterya.
  4. Insert two AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Ibalik ang tabon sa kompartamento sa baterya ug i-secure kini gamit ang screw.

4.2. Pagdugtong sa mga Test Lead

Close-up of FLUKE 15B MAX input jacks and rotary dial

Figure 2: Input jacks for test leads on the FLUKE 15B MAX.

  1. Insert the black test lead into the "COM" (common) input jack.
  2. For most voltage, resistance, capacitance, and diode measurements, insert the red test lead into the "VΩ" input jack.
  3. For current measurements (mA/µA), insert the red test lead into the "mAµA" input jack.
  4. For high current measurements (up to 10A), insert the red test lead into the "A" input jack.
  5. Ensure test leads are fully inserted and securely connected.

5. Mga Paagi sa Pagpalihok

The FLUKE 15B MAX features a rotary dial to select different measurement functions. The meter defaults to auto-ranging for most functions, simplifying operation.

atubangan view of FLUKE 15B MAX Digital Multimeter

Hulagway 3: Atubangan view of the multimeter showing the display, buttons, and rotary dial.

5.1. Function Selection (Rotary Dial)

  • PATAY: Turns the multimeter off.
  • V~ (AC Voltage): Measures alternating current voltage.
  • V- (DC Voltage): Measures direct current voltage.
  • mV~ (AC Millivolts): Measures small AC voltages.
  • Ω (Resistance): Nagsukod sa resistensya sa kuryente.
  • ))) (Continuity): Tests for continuity (a complete circuit). The meter will beep if continuity is detected.
  • -|- (Capacitance): Measures capacitance.
  • A~ (AC Amps): Measures alternating current.
  • A- (DC Amps): Measures direct current.
  • mA~ (AC Milliamps): Measures small alternating currents.
  • mA- (DC Milliamps): Measures small direct currents.
  • µA~ (AC Microamps): Measures very small alternating currents.
  • µA- (DC Microamps): Measures very small direct currents.

5.2. Mga Kalihokan sa Butang

  • PAGHIMO: Freezes the current reading on the display. Press again to release.
  • RANGE: Switches between auto-ranging and manual ranging. In manual ranging, press repeatedly to cycle through available ranges.
  • Backlight Button (Sun icon): Activates the display backlight for better visibility in low-light conditions.
  • Yellow Button (Function Select): For functions with multiple modes (e.g., AC/DC voltage, continuity/diode), press this button to toggle between modes.

5.3. Input Alert™ Feature

The Input Alert™ feature provides an audible and visual warning (flashing lights) if the test leads are incorrectly connected for the selected function. This helps prevent damage to the meter and potential hazards. Always ensure leads are in the correct jacks before making a measurement.

5.4. Using the 1mm Extra Tip Test Pen (for 15B MAX-02 and KIT models)

For precise measurements on small components or circuit boards, replace the standard test probe with the 1mm extra tip test pen. Its fine tip allows for accurate contact with individual pins and traces, minimizing the risk of short circuits.

6. Pagmentinar

6.1. Paglimpyo

Pagpahid sa kaso gamit ang adamp cloth and mild detergent. Do not use abrasives or solvents. Clean the terminals periodically with a cotton swab and alcohol to ensure good contact.

6.2. Pagpuli sa Baterya

When the battery indicator appears on the display, replace the batteries as described in the "Battery Installation" section (4.1). Always use two new AA batteries.

6.3. Pag-ilis sa Fuse

WARNING: To avoid injury or damage to the meter, replace blown fuses only with fuses of the specified type and rating.

If the meter fails to measure current, the fuse may be blown. Refer to the full user manual for detailed instructions on accessing and replacing the fuses. Typically, the meter uses two fuses: one for the mA/µA range and one for the A range.

6.4. Pagtipig

If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.

7. Pagsulbad sa problema

Problema Posibleng Hinungdan Solusyon
Meter does not power on. Patay o sayop nga na-install nga mga baterya. Check battery polarity, replace batteries.
"OL" (Overload) displayed. Measurement exceeds selected range or meter's maximum capacity. Open circuit. Switch to a higher range (if in manual mode), check for open circuit, ensure correct function is selected.
No current reading. Blown fuse, incorrect lead connection, or open circuit. Check/replace fuses, ensure red lead is in 'A' or 'mAµA' jack, check circuit continuity.
Dili tukma nga mga pagbasa. Low battery, dirty test leads/jacks, incorrect function/range, external interference. Replace batteries, clean leads/jacks, verify function/range, move away from strong electromagnetic fields.
Input Alert™ activates. Test leads are connected to the wrong input jacks for the selected function. Immediately correct the test lead connections to the appropriate input jacks.

8. Mga detalye

Feature Espesipikasyon
Ngalan sa Brand FLUKE
Numero sa Modelo 15BMAX
Uri sa Pagpakita Digital Display
Operating Mode Sakop sa Awto
Ang DC Voltage 1000V
Ang AC Voltage 1000V
DC Current 10A
Kasamtangan sa AC 10A
Pagsukod sa Range sa Pagsukol 40.00 MΩ
Pagsukod sa Capacitance Range 2000 μF
Measuring Inductance Range Refer to SPEC (Not specified in detail)
Operating Temperatura 0 - 40 ℃
Mga sukat 183 mm x 91 mm x 49.5 mm
Sertipikasyon CE
Mga Gamit sa DIY Elektrisidad
Mao ang Smart Device Dili
High-concerned nga kemikal Wala

9. Mga Tip sa Gumagamit

Here are some general tips to enhance your experience and ensure safe operation of your digital multimeter:

  • Always Start High: Kung gisukod ang wala mailhi nga voltage or current, always start with the highest range setting and work your way down. This prevents overloading the meter.
  • Check Test Leads: Before each use, visually inspect your test leads for any signs of damage (cracks, frayed insulation). Replace them immediately if damaged.
  • Luwas nga mga Koneksyon: Ensure test leads are firmly inserted into the correct input jacks and make good contact with the circuit points being measured.
  • Use the Kickstand: The integrated kickstand allows for hands-free operation, improving safety and convenience.
  • FLUKE 15B MAX Digital Multimeter with kickstand extended

    Figure 4: Multimeter shown with its kickstand for convenient viewing.

  • Understand "OL": An "OL" (Overload) reading typically means the value being measured is higher than the selected range or the meter's maximum capacity. It can also indicate an open circuit in resistance or continuity tests.
  • Kinabuhi sa Baterya: To conserve battery life, remember to turn off the multimeter when not in use.

10. Garantiya ug Suporta

For specific warranty information, please refer to the warranty card included with your product or the purchase documentation. In case of technical issues, questions, or the need for repair services, please contact the seller or the official FLUKE customer support in your region. Keep your proof of purchase for warranty claims.

Video 1: General overview of various Fluke testing equipment, including multimeters and thermal imagers.