1. Pasiuna
The UNI-T UT336B is a high-performance negative corona electronic leak detector designed for fast, accurate, and reliable detection of refrigerant leaks. Its advanced features make it an essential tool for professionals in various refrigeration-related fields. This manual provides detailed instructions for the safe and effective use of your UT336B detector.
The detector is capable of identifying various halogenated refrigerants, including CFCs (Chlorofluorocarbons), HCFCs (Hydrochlorofluorocarbons), and HFCs (Hydrofluorocarbons). This includes common refrigerants such as R12, R22, R32, R134a, R142, R502, R410a, and R123.

2. Impormasyon sa Kaluwasan
Please read and understand all safety warnings and operating instructions before using this product. Failure to do so may result in injury or damage to the device.
- Always operate the device in a well-ventilated area.
- Do not expose the device to extreme temperatures, humidity, or corrosive environments.
- Keep the device away from open flames or sparks.
- Ensure batteries are inserted correctly according to polarity markings.
- Replace batteries when the low battery indicator appears to ensure accurate readings.
- Do not attempt to repair or modify the device yourself. Contact qualified personnel for service.
3. Mga Sulod sa Pakete
Upon opening the package, please verify that all items listed below are present and in good condition. Note: The image below shows the UT336A model, which has similar package contents.
- UT336B Refrigerant Leakage Detector Unit: 1
- Spare Sensor Probe: 1
- 1.5V AA Batteries: 4
- Manwal sa Gumagamit: 1
- Certificate of Conformity + Warranty Card: 1

4. Mga Produkto sa Produkto
The UT336B Refrigerant Leakage Detector offers a range of features designed for efficient and precise leak detection:
- Taas nga pagkasensitibo: Capable of detecting minute leaks with a minimum sensitivity of 3g/a.
- 6-Level Sensitivity Adjustment: Allows users to select the appropriate sensitivity level for different leakage concentrations and environments.
- Acousto-Optic Alarm: Features a 6-level sound and light alarm system. Yellow, orange, and red LEDs provide visual warnings, with red indicating high concentration leaks. An audible alarm (beeping) accompanies the visual indicators.
- Innovative Probe Lamp Disenyo: Enhances visibility and provides clearer alarm indications.
- Automatic Zeroing: The device automatically resets upon startup, establishing the current environmental conditions as the zero baseline for accurate detection.
- LED Indikator sa Kuryente: Naghatag og klaro nga indikasyon sa kahimtang sa baterya.
- Mahigalaon sa Gumagamit nga Operasyon: Designed for simple and convenient use.


5. Mga detalye
| Hiyas | Bili |
|---|---|
| Numero sa Modelo | UT336B |
| Ngalan sa Brand | UNI-T |
| Gas Type Detected | CFCs, HCFCs, HFCs (e.g., R12, R22, R32, R134a, R142, R502, R410a, R123) |
| Minimum nga pagkasensitibo | 3g/a |
| Pagpahiangay sa Pagkasensitibo | 6 nga lebel |
| Indikasyon sa Alarm | 6-level acousto-optic (sound and yellow/orange/red LEDs) |
| Tinubdan sa Gahum | 4 x 1.5V AA Batteries (not included) |
| Kategoriya sa DIY Supplies | Elektrisidad |
| Sinugdanan | Mainland China |
| Mga Sertipikasyon | CE, FCC, RoHS, UL, KC, pse, weee |
| Gitas-on sa Pakete | 20 cm |
| Lapad sa Pakete | 16 cm |
| Gitas-on nga Package | 8 cm |
| Timbang sa Pakete | 0.6 kg |
6. Pag-setup
6.1 Pag-instalar sa Baterya
- Pangitaa ang tabon sa kompartamento sa baterya sa luyo sa aparato.
- Ablihi ang kompartamento sa baterya.
- Insert four (4) 1.5V AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Isira ang tabon sa kompartamento sa baterya nga lig-on.
6.2 Pagdugtong sa Probe
The detector comes with a flexible probe. Ensure it is securely attached to the main unit before use.
- Align the threaded end of the probe with the connection port on the top of the detector.
- Gently screw the probe into place until it is firm. Do not overtighten.
- The sensor tip is replaceable. To replace, unscrew the outer cap, remove the old sensor, insert the new one, and re-secure the cap.
7. Mga Instruksyon sa Pag-opera
7.1 Power On and Auto-Zero
- In a clean, fresh air environment (free from refrigerants), long-press the power button (usually the central button with a power symbol).
- The green LEDs will gradually light up and then extinguish, accompanied by a single beep.
- Subsequently, the yellow, orange, and red LEDs will illuminate fully and then extinguish.
- The device will emit a uniform "drip-drip" sound, and the power indicator light will turn green, indicating that the self-check is complete and the current ambient gas has been set as the zero point. The detector is now ready for use. This process typically takes about 3 seconds.
7.2 Pagpahiangay sa Pagkasensitibo
The UT336B features 6 levels of sensitivity. The default sensitivity upon startup is Level 3.
- Use the up (▲) and down (▼) arrow buttons to adjust the sensitivity.
- When adjusting, the green indicator lights will illuminate to show the current sensitivity level. More green lights indicate higher sensitivity.
- Choose a lower sensitivity for larger leaks or to pinpoint the source, and a higher sensitivity for detecting very small leaks.
7.3 Leak Detection Process
- With the detector powered on and zeroed, slowly move the probe tip around the suspected leak area.
- Maintain a steady, slow movement (e.g., 1-2 inches per second) to allow the sensor to react.
- If a refrigerant leak is detected, the device will emit an audible alarm (beeping) and the yellow, orange, and red LEDs will illuminate. The intensity of the alarm and the number of illuminated LEDs will correspond to the concentration of the detected refrigerant. Red LEDs indicate a high concentration.
- Continue to move the probe to pinpoint the exact source of the leak, observing the alarm intensity.
8. Mga Sitwasyon sa Aplikasyon
The UNI-T UT336B is versatile and suitable for various applications where refrigerant leak detection is critical:
- Air Conditioning Maintenance: Ideal for detecting leaks in residential, commercial, and industrial air conditioning systems.
- Automobile Maintenance: Essential for checking refrigerant leaks in automotive AC systems.
- Industrial Refrigeration Industry: Used in large-scale refrigeration systems, cold storage facilities, and industrial chillers.
- Refrigerator Maintenance: Suitable for diagnosing leaks in household refrigerators and freezers.
- Medikal nga Kagamitan: Can be used for systems utilizing refrigerants in medical devices.
- Laboratory Equipment: Applicable for laboratory apparatus that incorporate refrigeration cycles.

9. Pagmentinar
9.1 Kinatibuk-ang Pag-atiman
- Keep the detector clean and dry. Wipe the exterior with a soft, damp panapton. Ayaw gamita ang mga abrasive nga panglimpyo o mga solvent.
- Itago ang aparato sa usa ka bugnaw, uga nga lugar kung dili gamiton, layo sa direkta nga adlaw ug grabe nga temperatura.
- Protect the probe tip from physical damage.
9.2 Pagpuli sa Sensor
The sensor probe is a consumable part and may require replacement over time due to wear or contamination. A spare sensor probe is included in the package.
- Siguroha nga ang device gipalong.
- Carefully unscrew the outer cap of the probe tip.
- Remove the old sensor element.
- Insert the new sensor element, ensuring it is seated correctly.
- Screw the outer cap back onto the probe tip securely.
- After replacing the sensor, perform the auto-zero procedure in a fresh air environment before conducting leak detection.
10. Pagsulbad sa problema
If you encounter issues with your UT336B detector, please refer to the following common problems and solutions:
- Walay Gahum: Check if the batteries are correctly installed and fully charged. Replace with new batteries if necessary.
- Inaccurate Readings/False Alarms: Ensure the device was zeroed in a clean, fresh air environment. Move to a different area and re-zero. The sensor might be contaminated or nearing the end of its lifespan; consider replacing the sensor probe.
- Weak or No Alarm: Check the sensitivity setting. Increase sensitivity if needed. Ensure the probe is positioned correctly near the potential leak source.
- Device Dili Motubag: Try removing and reinserting the batteries. If the issue persists, contact customer support.
11. Mga Tip sa Gumagamit
- For best results, always perform the auto-zero function in an area known to be free of refrigerants before starting your inspection.
- Move the probe slowly and steadily around potential leak points. Rapid movement can reduce detection accuracy.
- When checking for leaks in complex systems, start with the highest sensitivity and gradually decrease it to pinpoint the exact leak location once a general area is identified.
- Keep the sensor tip clean to maintain optimal performance.
12. Mga Sertipikasyon
The UNI-T UT336B Refrigerant Leakage Detector complies with various international standards and holds the following certifications:
- CE
- FCC
- RoHS
- UL
- KC
- pse
- weee
13. Garantiya ug Suporta
Alang sa impormasyon sa warranty, teknikal nga suporta, o mga pangutana bahin sa serbisyo, palihug tan-awa ang warranty card nga gilakip sa imong pakete o kontaka direkta ang nagbaligya. Itago ang imong resibo sa pagpalit isip pruweba sa pagpalit.