1. Pasiuna
The AT1-4000X Variable Frequency Drive (VFD) is designed to provide precise speed control for 3-phase 4kW AC motors, operating from a single-phase 220V AC input. This VFD utilizes a unique control method to achieve high torque, high accuracy, and a wide speed regulating range, ensuring high performance in various applications.
Ang panguna nga mga bahin naglakip sa:
- Excellent anti-trip performance and adaptability to challenging power conditions, temperature fluctuations, humidity, and dust interference, significantly enhancing stability.
- Optimized PWM control technology and electromagnetic compatibility for low noise and reduced electromagnetic interference.
- User-friendly design for easy operation and wiring.
- Fast start and stop response with substantial torque at low speeds.
2. Mga Pag-amping sa Kaluwasan
Failure to follow these instructions may result in death, serious injury, or significant property loss.
- Siguruha kanunay nga naputol ang suplay sa kuryente sa dili pa mohimo sa bisan unsang mga kable o maintenance.
- Never connect the U/V/W output terminals to the AC power supply. Doing so will cause severe damage to the inverter.
- Do not install the inverter in environments with flammable or explosive gases, as this poses a risk of explosion.
- The ground terminal (GND) of the inverter must be properly and securely grounded.
- Only qualified professionals should perform internal wiring or open the inverter's casing due to the presence of high voltage.

3. Tapos sa Produktoview
The AT1-4000X VFD features a clear digital display and an intuitive control panel for easy monitoring and adjustment of motor parameters. The unit is designed for efficient heat dissipation with integrated cooling fins and fans.
3.1 Control Panel
Ang atubangan nga panel naglakip sa:
- Digital nga Display: Shows operational parameters such as frequency (Hz), forward/reverse status (FWD/REV), and revolutions per minute (r/min).
- Mga timailhan: Power, Hz, FWD, REV, r/min.
- Butang:
DISP: Display mode selection.PROG: Program mode entry/exit.FUNC/DATA: Function/Data entry.FWD/REV: Forward/Reverse direction control.▲(Up Arrow): Increase value or navigate menus.▼(Down Arrow): Decrease value or navigate menus.RUN: Start motor operation.STOP/RESET: Stop motor operation or reset errors.
- Rotary Knob: For fine adjustment of frequency or parameter values.
3.2 Mga terminal
The VFD is equipped with clearly labeled terminals for power input and motor output.

4. Mga detalye
| Feature | Espesipikasyon |
|---|---|
| Modelo | AT1-4000X |
| Gihatagan og bili nga Voltage (Input) | AC 220V (Usa ka Hugna) |
| Angay nga Gahom sa Motor | 4kW |
| Pamaagi sa Pagkontrol | V/F Bukas nga Loop |
| Output Voltage Mapasibo nga Pamaagi | Pagkontrol sa PWM |
| Rated Output Current | 20A |
| Maximum Output Frequency Range | 0 - 400Hz |
| Type | Inverter Motor Drive |
| Sinugdanan | Mainland China |
| Mga Dimensyon sa Pakete (L x W x H) | 23 cm x 23 cm x 16 cm |
| Timbang sa Pakete | 1.498 kg |
5. Pag-setup
Before proceeding with installation and wiring, ensure all safety precautions are understood and followed. Installation should be performed by qualified personnel.
5.1 Kalibutan sa Pag-instalar
- Install the VFD in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, high temperatures, excessive humidity, and dusty environments.
- Ensure there is sufficient space around the unit for proper heat dissipation.
- Ayaw pag-instalar duol sa mga materyales nga dali masunog o mobuto.
5.2 Mga Instruksyon sa Wiring
The VFD is designed for simple wiring. Always ensure the power supply is OFF before connecting any wires. Connect wires after removing the terminal screws.

| Terminal | Kalihokan | Deskripsyon |
|---|---|---|
| L, N | AC 220V Input | Connect to single-phase AC 220V power supply. |
| U, V, W | 3-Phase AC Motor Output | Connect to the three-phase AC motor terminals. |
| GND | Yuta | Ikonektar sa usa ka kasaligan nga ground ground. |
6. Mga Instruksyon sa Pag-opera
Once the VFD is correctly installed and wired, you can begin operation. Familiarize yourself with the control panel functions.
6.1 Basic nga Operasyon
- Gahum sa: Ensure all connections are secure, then apply single-phase 220V AC power to the L and N terminals. The VFD display should illuminate.
- Pagsugod sa Motor: Pindota ang
RUNbutton to start the motor. The FWD or REV indicator will light up depending on the current direction setting. - Adjust Frequency/Speed: Use the rotary knob to adjust the output frequency, which in turn controls the motor speed. The display will show the current frequency (Hz) or RPM (r/min).
- Usba ang Direksyon: Pindota ang
FWD/REVbutton to toggle the motor's rotation direction. - Hunonga ang Motor: Pindota ang
STOP/RESETbuton aron ihunong ang motor.
6.2 Parameter Programming
Ang PROG ug FUNC/DATA buttons, along with the arrow keys (▲, ▼), are used to access and modify various operating parameters. Refer to the detailed programming manual (if available) for specific parameter settings relevant to your application.
- Press
PROGto enter or exit programming mode. - Paggamit
▲ug▼to navigate through parameter groups or individual parameters. - Press
FUNC/DATAto select a parameter for editing or to confirm a value. - Use the rotary knob or arrow keys to change the parameter value.
- Press
FUNC/DATAagain to save the new value.
7. Pagmentinar
Ang regular nga pagmentinar makatabang sa pagsiguro sa kalig-on ug kasaligan nga operasyon sa imong VFD.
- Paglimpyo: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- bentilasyon: Ensure that the cooling fans and ventilation openings are not obstructed to prevent overheating.
- Inspeksyon: Periodically inspect all wiring connections for tightness and signs of wear or damage.
- Propesyonal nga Serbisyo: Due to high internal voltages, any internal inspection or repair should only be performed by qualified service personnel. Do not attempt to open the VFD casing imong kaugalingon.
8. Pagsulbad sa problema
Kini nga seksyon naghatag ug kinatibuk-ang giya alang sa kasagarang mga isyu. Alang sa komplikado nga mga problema, kontaka ang teknikal nga suporta.
| Problema | Posibleng Hinungdan | Solusyon |
|---|---|---|
| Dili moandar ang VFD | No input power; Incorrect wiring | Check power supply and input wiring (L, N). |
| Dili moandar ang motor | Motor wiring incorrect; VFD in STOP mode; Parameter error | Verify motor wiring (U, V, W); Press RUN; Check programmed parameters. |
| Dili stable ang katulin sa motor | Incorrect V/F settings; Motor load fluctuations | Adjust V/F curve parameters; Ensure motor is suitable for load. |
| Sobra nga karga sayop | Motor overloaded; Incorrect overload protection setting | Reduce motor load; Check and adjust overload protection parameters. |
If an error occurs, the VFD display may show an error code. Press the STOP/RESET button to clear the error after addressing the cause.
9. Mga Tip sa Gumagamit
- For optimal performance, ensure the VFD is matched correctly to your motor's power rating (e.g., 4kW motor for this 4kW VFD).
- When adjusting frequency, make gradual changes to avoid sudden motor stress.
- Always ensure proper grounding to prevent electrical hazards and ensure stable operation.
- Keep the VFD's ventilation clear to prevent overheating, especially during continuous operation.
10. Garantiya ug Suporta
For warranty information, technical support, or service inquiries, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase records handy when seeking support.