Mga Detalye sa Produkto

  • Brand: CMSElectracom
  • Ngalan sa Produkto: Retractable Cable Reel
  • Mga Posisyon sa Mounting Hole: 311 x 293 mm
  • Pagkontrol: Pagkontrol sa pendant nga adunay pag-adjust sa puwersa sa pagkasensitibo
  • Wiring: Black – Negative, Red – Positive, Green/Yellow – Earth

NOTA

  • ELECTRICAL WIRING TO BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.

IF THE SUPPLY CORD IS DAMAGED, IT SHALL BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARLY QUALIFIED PERSON TO AVOID HAZARD. DISCONNECT THE EQUIPMENT FROM THE MAIN SUPPLY BEFORE OPENING THE COVER.

CMS-Electracom-Elevate-Retractable-Power Module-fig- (1)

CMS-Electracom-Elevate-Retractable-Power Module-fig- (2)

Pagbutang sa kusog nga overload

  • Press and hold SET until the creen displays P1, press DOWN once, the display will show P2, Press SET once again. The display will show F5. Press UP until the display shows F1.
  • Press SET to confirm sthe setting.
  • The display will show — to show setting is complete.

CMS-Electracom-Elevate-Retractable-Power Module-fig- (3)

Pag-set up ug Down Posisyon

Press and hold SET until the screen displays P1, press SET again, and the Display will show OP. Press and hold DOWN until the pendant is inthe correct position for use, then press SET.The T Display will show CL. Press and hold UP until the pendant is in the correct home position, then press SET. The pendant will now move to the home positions automatically to map the up and down sensitivity force requirements.

CMS-Electracom-Elevate-Retractable-Power Module-fig- (4)

Pagdugang sa mga transmiter ug RF switch

  • Press and hold CODE until the screen displays SU
  • Press a button you would like to set on the transmitter, then release and press the same button again.
  • The display will flash S, U The display will show — to show setting is complete.

To cancel stored codes

  • Press and hold CODE for more than 8 seconds until it flashes dL
  • Clearing H error code- press and hold SET until uuntilscthe screen displays P1, press up to P3, push SET- if H1 appears, push down to H0, push SET to finish.

CMS-Electracom-Elevate-Retractable-Power Module-fig- (5)

CMS-Electracom-Elevate-Retractable-Power Module-fig- (6)

Mounting the Cable Reel

  1. Remove the cover plate and cable strain components.
  2. Guntinga ang cable sa gitinguha nga gitas-on.
  3. Feed the cable through the roller and around the reel, ensuring at least one loop.
  4. Kuhaa ang cable pagkahuman sa cable strain plate.
  5. Connect wires to the terminal block: Black – Negative, Red – Positive, Green/Yellow – Earth.
  6. I-secure ang cable strain plate gamit ang 2 x M3 screws.
  7. I-screw balik ang cover plate ngadto sa cable reel.

Setting Force Overload and Positions

  1. To set force overload, press and hold SET until the screen displays P1. Press DOWN once to reach F5, then adjust to F1 and press SET to confirm.
  2. To set up and down positions, press and hold SET until P1 is displayed. Press SET again to reach OP. Adjust the pendant position by holding DOWN and SET for the down position and UP and SET for the up position.

Adding Transmitters and RF Switches

  1. Press and hold CODE until SU is displayed. Press a button on the transmitter, then press it again. Wait for the setting to complete.
  2. To cancel stored codes, hold CODE for more than 8 seconds until it flashes dL.

Installation on Ceiling Tile

  1. Cut a provision into the ceiling tile where the power pole is dropping from the Elevate unit.
  2. I-bolt ang suporta sa limit switch sa ibabaw nga plato.
  3. Secure the top plate onto the guide using the hex nuts provided.
  4. Position the power pole flush to the ceiling tile and secure the limit switch to a bracket using 2 x M4 screws and hex nuts.

Mga FAQ

Can I replace the supply cord if it's damaged?

Electrical wiring should be carried out by a qualified person. If the supply cord is damaged, it must be replaced by the manufacturer or a similarly qualified person to avoid hazards.

How do I clear an H error code?

Press and hold SET until P1 is displayed. Press up to P3, then push SET. If H1 appears, push down to H0 and press SET to finish.